Viscosity and temperature

It is generally believed that the volume flow measured by the electromagnetic flowmeter is not affected by the viscosity and temperature of the liquid. However, the test proves that it will be affected. The conclusion of the following test example 1. The influence of liquid viscosity Modulated sugar, water solution, and glycerin, water solution is

Viscosity and temperature Read More »

The main sources of electromagnetic flowmeter failures caused by piping systems and related equipment are as follows

Poor installation Not full tube Gas storage in the piping system Constantly inhale gas Flow status changes during use 1. Poor installation Poor installation is manifested in: The flow sensor and the inner diameter of the connecting pipe are incorrectly matched, and the difference is too large. Without the manufacturer’s recommendation, the inner diameter of

The main sources of electromagnetic flowmeter failures caused by piping systems and related equipment are as follows Read More »

electromagnetic flow meter failure caused by environment

1. Strong magnetic field Since it is generally noted to be far away from the strong magnetic field during installation, there are not many cases where the strong magnetic field affects the practice. 2. Strong electromagnetic wave The electromagnetic flowmeter should meet the requirements of electromagnetic compatibility, work normally under the specified radiated electromagnetic field

electromagnetic flow meter failure caused by environment Read More »