admin_zero, Author at Just Measure it - Page 247 of 356

admin_zero

Application and advantages of ultrasonic liquid level meter in diethyl maleate liquid level measurement

Ultrasonic liquid level meter is a high-precision instrument widely used in liquid level measurement, and its application in different liquids has been widely verified. In chemical production, diethyl maleate (MES for short) is a common organic solvent, and its liquid level measurement is crucial for the control of the production process. This article will discuss […]

Application and advantages of ultrasonic liquid level meter in diethyl maleate liquid level measurement Read More »

Metal float flowmeter installation specifications

Metal float flowmeter is a commonly used flow measurement instrument. Correct installation is crucial to the accuracy and stability of the flowmeter. The following are the installation specifications for metal float flowmeters: 1. Installation location selection: The metal float flowmeter should be installed on the horizontal section of the pipeline, at least 5 times the

Metal float flowmeter installation specifications Read More »

Brief Analysis on Measuring Enzyme Liquid Level with Radar Level Meter

In the bioengineering and pharmaceutical industries, the storage and monitoring of enzyme solutions is a critical process. Due to the special properties of enzyme solutions, some level measurement methods often fail to achieve the expected accuracy. Radar level meters, with their non-contact measurement advantages, have demonstrated significant performance in this field. As a biocatalyst, enzyme

Brief Analysis on Measuring Enzyme Liquid Level with Radar Level Meter Read More »

DN25 Temperature and pressure compensation integrated vortex flowmeter

Temperature and pressure compensation integrated vortex flowmeter, Accuracy 1.5%, On-site display +4-20ma output, DC24V external power supply, 304 stainless steel meter body, Temperature resistance <350℃, National standard flange clamping installation (including matching carbon steel flange bolt pads Chip nut), Not explosion-proof, Protection grade IP65, Pressure resistance 4.0mpaDN25: 9-55m³/h

DN25 Temperature and pressure compensation integrated vortex flowmeter Read More »

Application of ultrasonic liquid level meter in mine slurry level monitoring

As an important resource extraction site, mines often involve the transportation and storage of slurry during their production process. In mining production, accurate and reliable monitoring of slurry level is crucial for production efficiency and safety. As a high-precision liquid level measurement equipment, ultrasonic liquid level meter plays an important role in mine slurry level

Application of ultrasonic liquid level meter in mine slurry level monitoring Read More »

DN25 Coriolis Mass flowmeter

Coriolis Mass flowmeter Model: ZE-CGQ-025LAW1S1.6IF0.2D Micro bend type sensor Flanged connection: DIN 2501 DN25mm PN16 RF Flow range: Max. 300-8000kg/hr Accuracy: 0.2%, Max. pressure: 1.6MPa Process temperature: -50 to 125℃, Sensor tubes and: SS316L, flanges and spliter SS304 Integral type transmitter Power supply: 230VAC 50/60HZ II 2G Exdb IIB/IIC T*Gb , ATEX and IECEX approved

DN25 Coriolis Mass flowmeter Read More »

Revealing six major misunderstandings in the installation of radar level gauges

In the field of industrial measurement and control, radar level gauges are favored for their high accuracy, non-contact measurement and wide applicability. However, despite its increasingly mature technology, there are still some common misunderstandings during the installation process. If these misunderstandings are not corrected, they will seriously affect the measurement effect of the liquid level

Revealing six major misunderstandings in the installation of radar level gauges Read More »

DN1400 mm MIK-LDG Insertion type electromagnetic flowmeter

·         MIK-LDG Insertion type electromagnetic flowmeter ·         Pipe size: DN1400 mm ·         Nominal Pressure: 16 bar ·         Accuracy: 1.5% ·         Probe: Polyurethane ·         Electrode: Hastelloy C ·         IP 67 ·        Voltage  380/220 Vac /50 Hz ·         4-20 mA output ·         Flowmetre for raw water from the government irrigation agency

DN1400 mm MIK-LDG Insertion type electromagnetic flowmeter Read More »

2” ANSI B16.5 300LB RF Coriolis Mass flowmeter

Coriolis Mass flowmeter Model: ZE-CGQ-050LCW1H300IF0.1D Micro bend type sensor Flanged connection: 2” ANSI B16.5 300LB RFFlow range: Max. 10-24ton/hrAccuracy: 0.1%,Max. pressure: 5MPaProcess temperature: -50 to 350℃,Sensor tubes and: SS316L, flanges and spliter SS316L Remote type transmitter with 5m cables Power supply: 230VAC 50/60HZ II 2G Exdb IIB/IIC T*Gb , ATEX and IECEX approved for hazardous

2” ANSI B16.5 300LB RF Coriolis Mass flowmeter Read More »

Application of radar level gauge in original pool water level measurement

The accurate water level measurement of the original pool is not only related to the effective management of water resources, but also directly affects the stability of the subsequent treatment process and the quality of the final water supply. With the advancement of science and technology, radar level gauges have become an ideal choice for

Application of radar level gauge in original pool water level measurement Read More »

Translate »